"0": "Success" "272": "Invalid block number" "273": "Invalid request length" "274": "Invalid parameter" "275": "Invalid block type" "276": "Block not found" "277": "Block already exists" "278": "Block is write-protected" "279": "The block/operating system update is too large" "280": "Invalid block number" "281": "Incorrect password entered" "282": "PG resource error" "283": "PLC resource error" "284": "Protocol error" "285": "Too many blocks (module-related restriction)" "286": "There is no longer a connection to the database, or S7DOS handle is invalid" "287": "Result buffer too small" "288": "End of block list" "320": "Insufficient memory available" "321": "Job cannot be processed because of a lack of resources" "32769": "The requested service cannot be performed while the block is in the current status" "32771": "S7 protocol error: Error occurred while transferring the block" "33024": "Application, general error: Service unknown to remote module" "33028": "This service is not implemented on the module or a frame error was reported" "33284": "The type specification for the object is inconsistent" "33285": "A copied block already exists and is not linked" "33537": "Insufficient memory space or work memory on the module, or specified storage medium not accessible" "33538": "Too few resources available or the processor resources are not available" "33540": "No further parallel upload possible. There is a resource bottleneck" "33541": "Function not available" "33542": "Insufficient work memory (for copying, linking, loading AWP)" "33543": "Not enough retentive work memory (for copying, linking, loading AWP)" "33793": "S7 protocol error: Invalid service sequence (for example, loading or uploading a block)" "33794": "Service cannot execute owing to status of the addressed object" "33796": "S7 protocol: The function cannot be performed" "33797": "Remote block is in DISABLE state (CFB). The function cannot be performed" "34048": "S7 protocol error: Wrong frames" "34051": "Alarm from the module: Service canceled prematurely" "34561": "Error addressing the object on the communications partner (for example, area length error)" "34562": "The requested service is not supported by the module" "34563": "Access to object refused" "34564": "Access error: Object damaged" "53249": "Protocol error: Illegal job number" "53250": "Parameter error: Illegal job variant" "53251": "Parameter error: Debugging function not supported by module" "53252": "Parameter error: Illegal job status" "53253": "Parameter error: Illegal job termination" "53254": "Parameter error: Illegal link disconnection ID" "53255": "Parameter error: Illegal number of buffer elements" "53256": "Parameter error: Illegal scan rate" "53257": "Parameter error: Illegal number of executions" "53258": "Parameter error: Illegal trigger event" "53259": "Parameter error: Illegal trigger condition" "53265": "Parameter error in path of the call environment: Block does not exist" "53266": "Parameter error: Wrong address in block" "53268": "Parameter error: Block being deleted/overwritten" "53269": "Parameter error: Illegal tag address" "53270": "Parameter error: Test jobs not possible, because of errors in user program" "53271": "Parameter error: Illegal trigger number" "53285": "Parameter error: Invalid path" "53286": "Parameter error: Illegal access type" "53287": "Parameter error: This number of data blocks is not permitted" "53297": "Internal protocol error" "53298": "Parameter error: Wrong result buffer length" "53299": "Protocol error: Wrong job length" "53311": "Coding error: Error in parameter section (for example, reserve bytes not equal to 0)" "53313": "Data error: Illegal status list ID" "53314": "Data error: Illegal tag address" "53315": "Data error: Referenced job not found, check job data" "53316": "Data error: Illegal tag value, check job data" "53317": "Data error: Exiting the ODIS control is not allowed in HOLD" "53318": "Data error: Illegal measuring stage during run-time measurement" "53319": "Data error: Illegal hierarchy in 'Read job list'" "53320": "Data error: Illegal deletion ID in 'Delete job'" "53321": "Invalid substitute ID in 'Replace job'" "53322": "Error executing 'program status'" "53343": "Coding error: Error in data section (for example, reserve bytes not equal to 0, ...)" "53345": "Resource error: No memory space for job" "53346": "Resource error: Job list full" "53347": "Resource error: Trigger event occupied" "53348": "Resource error: Not enough memory space for one result buffer element" "53349": "Resource error: Not enough memory space for several result buffer elements" "53350": "Resource error: The timer available for run-time measurement is occupied by another job" "53351": "Resource error: Too many 'modify tag' jobs active (in particular multi-processor operation)" "53377": "Function not permitted in current mode" "53378": "Mode error: Cannot exit HOLD mode" "53409": "Function not permitted in current protection level" "53410": "Function not possible at present, because a function is running that modifies memory" "53411": "Too many 'modify tag' jobs active on the I/O (in particular multi-processor operation)" "53412": "'Forcing' has already been established" "53413": "Referenced job not found" "53414": "Job cannot be disabled/enabled" "53415": "Job cannot be deleted, for example because it is currently being read" "53416": "Job cannot be replaced, for example because it is currently being read or deleted" "53417": "Job cannot be read, for example because it is currently being deleted" "53418": "Time limit exceeded in processing operation" "53419": "Invalid job parameters in process operation" "53420": "Invalid job data in process operation" "53421": "Operating mode already set" "53422": "The job was set up over a different connection and can only be handled over this connection" "53441": "At least one error has been detected while accessing the tag(s)" "53442": "Change to STOP/HOLD mode" "53443": "At least one error was detected while accessing the tag(s). Mode change to STOP/HOLD" "53444": "Timeout during run-time measurement" "53445": "Display of block stack inconsistent, because blocks were deleted/reloaded" "53446": "Job was automatically deleted as the jobs it referenced have been deleted" "53447": "The job was automatically deleted because STOP mode was exited" "53448": "'Block status' aborted because of inconsistencies between test job and running program" "53449": "Exit the status area by resetting OB90" "53450": "Exiting the status range by resetting OB90 and access error reading tags before exiting" "53451": "The output disable for the peripheral outputs has been activated again" "53452": "The amount of data for the debugging functions is restricted by the time limit" "53761": "Syntax error in block name" "53762": "Syntax error in function parameters" "53765": "Linked block already exists in RAM: Conditional copying is not possible" "53766": "Linked block already exists in EPROM: Conditional copying is not possible" "53768": "Maximum number of copied (not linked) blocks on module exceeded" "53769": "(At least) one of the given blocks not found on the module" "53770": "The maximum number of blocks that can be linked with one job was exceeded" "53771": "The maximum number of blocks that can be deleted with one job was exceeded" "53772": "OB cannot be copied because the associated priority class does not exist" "53773": "SDB cannot be interpreted (for example, unknown number)" "53774": "No (further) block available" "53775": "Module-specific maximum block size exceeded" "53776": "Invalid block number" "53778": "Incorrect header attribute (run-time relevant)" "53779": "Too many SDBs. Note the restrictions on the module being used" "53782": "Invalid user program - reset module" "53783": "Protection level specified in module properties not permitted" "53784": "Incorrect attribute (active/passive)" "53785": "Incorrect block lengths (for example, incorrect length of first section or of the whole block)" "53786": "Incorrect local data length or write-protection code faulty" "53787": "Module cannot compress or compression was interrupted early" "53789": "The volume of dynamic project data transferred is illegal" "53790": "Unable to assign parameters to a module (such as FM, CP). The system data could not be linked" "53792": "Invalid programming language. Note the restrictions on the module being used" "53793": "The system data for connections or routing are not valid" "53794": "The system data of the global data definition contain invalid parameters" "53795": "Error in instance data block for communication function block or maximum number of instance DBs exceeded" "53796": "The SCAN system data block contains invalid parameters" "53797": "The DP system data block contains invalid parameters" "53798": "A structural error occurred in a block" "53808": "A structural error occurred in a block" "53809": "At least one loaded OB cannot be copied because the associated priority class does not exist" "53810": "At least one block number of a loaded block is illegal" "53812": "Block exists twice in the specified memory medium or in the job" "53813": "The block contains an incorrect checksum" "53814": "The block does not contain a checksum" "53815": "You are about to load the block twice, i.e. a block with the same time stamp already exists on the CPU" "53816": "At least one of the blocks specified is not a DB" "53817": "At least one of the DBs specified is not available as a linked variant in the load memory" "53818": "At least one of the specified DBs is considerably different from the copied and linked variant" "53824": "Coordination rules violated" "53825": "The function is not permitted in the current protection level" "53826": "Protection violation while processing F blocks" "53840": "Update and module ID or version do not match" "53841": "Incorrect sequence of operating system components" "53842": "Checksum error" "53843": "No executable loader available; update only possible using a memory card" "53844": "Storage error in operating system" "53888": "Error compiling block in S7-300 CPU" "53921": "Another block function or a trigger on a block is active" "53922": "A trigger is active on a block. Complete the debugging function first" "53923": "The block is not active (linked), the block is occupied or the block is currently marked for deletion" "53924": "The block is already being processed by another block function" "53926": "It is not possible to save and change the user program simultaneously" "53927": "The block has the attribute 'unlinked' or is not processed" "53928": "An active debugging function is preventing parameters from being assigned to the CPU" "53929": "New parameters are being assigned to the CPU" "53930": "New parameters are currently being assigned to the modules" "53931": "The dynamic configuration limits are currently being changed" "53932": "A running active or deactivate assignment (SFC 12) is temporarily preventing R-KiR process" "53936": "An error occurred while configuring in RUN (CiR)" "53952": "The maximum number of technological objects has been exceeded" "53953": "The same technology data block already exists on the module" "53954": "Downloading the user program or downloading the hardware configuration is not possible" "54273": "Information function unavailable" "54274": "Information function unavailable" "54275": "Service has already been logged on/off (Diagnostics/PMC)" "54276": "Maximum number of nodes reached. No more logons possible for diagnostics/PMC" "54277": "Service not supported or syntax error in function parameters" "54278": "Required information currently unavailable" "54279": "Diagnostics error occurred" "54280": "Update aborted" "54281": "Error on DP bus" "54785": "Syntax error in function parameter" "54786": "Incorrect password entered" "54787": "The connection has already been legitimized" "54788": "The connection has already been enabled" "54789": "Legitimization not possible because password does not exist" "55297": "At least one tag address is invalid" "55298": "Specified job does not exist" "55299": "Illegal job status" "55300": "Illegal cycle time (illegal time base or multiple)" "55301": "No more cyclic read jobs can be set up" "55302": "The referenced job is in a state in which the requested function cannot be performed" "55303": "Function aborted due to overload, meaning executing the read cycle takes longer than the set scan cycle time" "56321": "Date and/or time invalid" "57857": "CPU is already the master" "57858": "Connect and update not possible due to different user program in flash module" "57859": "Connect and update not possible due to different firmware" "57860": "Connect and update not possible due to different memory configuration" "57861": "Connect/update aborted due to synchronization error" "57862": "Connect/update denied due to coordination violation" "61185": "S7 protocol error: Error at ID2; only 00H permitted in job" "61186": "S7 protocol error: Error at ID2; set of resources does not exist"